Fine bitumen droplets dispersed in water with an emulsifier. Charge, setting behaviour and aggregate compatibility determine the right product. Emulsion and recovered-binder tests must be considered separately. Tack coats, surface treatments and cold mixes can call for different emulsion grades even on the same project. Share the intended treatment, aggregate information and specified setting class, together with the required tests and storage arrangements.
Reference limits from the SRNT catalogue, not measured batch results or a COA. Availability, the applicable standard edition and contractual limits are confirmed for each enquiry.
| Property / condition | Unit | Reference limit | Test method |
|---|---|---|---|
| TESTS ON EMULSION | |||
| Saybolt Furol viscosity at 25°C | SFS | 20-100 | ASTM D7496 |
| Storage stability, 24 h | % | ≤1 | ASTM D6930 |
| Particle charge | - | Positive | ASTM D7402 |
| Sieve test | % | ≤0.10 | ASTM D6933 |
| Cement mixing | % | ≤2 | ASTM D6935 |
| Residue by distillation | % | ≥57 | ASTM D6997 |
| TESTS ON RESIDUE FROM DISTILLATION | |||
| Penetration at 25°C, 100 g, 5 s | 0.1 mm | 40-90 | ASTM D5 |
| Ductility at 25°C, 5 cm/min | cm | ≥40 | ASTM D113 |
| Solubility in trichloroethylene | % | ≥97.5 | ASTM D2042 |
Emulsion tests and recovered-binder tests are separate. Use the recovery method and conditions shown; confirm the required specification edition and application-specific tests with your enquiry.
Grade selection also depends on the aggregate and intended treatment. Packaging, handling conditions, storage
period and final specifications are confirmed for each enquiry.
Catalogue PDF